Rorke Data The Galaxy 65 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Macierze dyskowe Rorke Data The Galaxy 65. Rorke Data The Galaxy 65 Product specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 129
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Galaxy RAID
Model GHDX2-2430S-24F4D
24 bay FC-4G to SATA-II RAID Subsystem
Single Controller
Model GHDX2-2430R-24F4D
24 bay FC-4G to SATA-II RAID Subsystem
Dual Controller
Installation and Hardware
Reference Manual
Version 1007
Version 1.0 (08, 2005)
Przeglądanie stron 0
1 2 3 4 5 6 ... 128 129

Podsumowanie treści

Strona 1 - Reference Manual

Galaxy RAID Model GHDX2-2430S-24F4D 24 bay FC-4G to SATA-II RAID Subsystem Single Controller Model GHDX2-2430R-24F4D 24 bay FC-

Strona 2 - Contact Information

Galaxy Raid GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual x C.2. COM1 CABLE: DB9 AUDIO JACK PIN OUTS ...

Strona 3 - Copyright 2007

Chapter 5: Subsystem Maintenance Subsystem Maintenance 5-5 Step 2. If working on the dual-controller Galaxy HDX2, the workload should have been

Strona 4 - Warnings and Certifications

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 5-6 Subsystem Maintenance positions, the controller module will automatically

Strona 5

Chapter 5: Subsystem Maintenance Subsystem Maintenance 5-7 Step 2. Install the BBU module onto the replacement controller. You may need to insta

Strona 6

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 5-8 Subsystem Maintenance Step 6. Power up the system. Please follow the co

Strona 7 - Table of Contents

Chapter 5: Subsystem Maintenance Subsystem Maintenance 5-9 BBU failure can result from the following: 1. A BBU (Battery Backup Unit) has lost it

Strona 8

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 5-10 Subsystem Maintenance NOTE: 1. The chance of BBU charger failure is c

Strona 9

Chapter 5: Subsystem Maintenance Subsystem Maintenance 5-11 Figure 5-6: Removing the Power Cord Step 2. Remove the retention screw underneath t

Strona 10

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 5-12 Subsystem Maintenance Figure 5-8: Dislodging the PSU Step 4. Gently pu

Strona 11 - Safety Precautions

Chapter 5: Subsystem Maintenance Subsystem Maintenance 5-13 Step 6. Insert and fasten the retention screw underneath the extraction handle to se

Strona 12 - Related Documentation

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 5-14 Subsystem Maintenance  Replacing a cooling module: When you are notifie

Strona 13 - IMPORTANT!

Galaxy Raid Installation and Hardware Reference Manual xi Safety Precautions Precautions and Instructions • Prior to powering on the subsystem,

Strona 14

Chapter 5: Subsystem Maintenance Subsystem Maintenance 5-15 5.6. Drive Tray Maintenance 5.6.1 Notes on Hard Drive Maintenance  Hot-swappable dri

Strona 15

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 5-16 Subsystem Maintenance Step 5. Remove the retention screws on the sides

Strona 16 - Introduction

Chapter 5: Subsystem Maintenance Subsystem Maintenance 5-17 This page is intentionally left blank.

Strona 17 - 1.1.1.1 Chassis Overview

Specifications A-1 Appendix A Subsystem Specifications A.1. Technical Specifications Environmental Specifications Humidity 5% to 95% (non conden

Strona 18 - 1.1.1.2 Physical Dimensions

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual A-2 Specifications Certifications • FCC Class-A • CE • CB • UL60950 / IE

Strona 19 - 1.1.1.4 Drive Slot Numbering

Appendix A: Subsystem Specifications Specifications A-3 A.2. Controller Functional Specifications Specification RAID Levels 0, 1(0 + 1), 3, 5, 6,

Strona 20 - 1.1.1.5 Rear Panel Overview

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual A-4 Specifications A.4. Power Supply Specifications Specification Nominal Po

Strona 21 - 1.2. Subsystem Components

Appendix A: Subsystem Specifications Specifications A-5 A.6. RAID Management Specification Configuration • LCD keypad panel • Text-based firmware

Strona 22 - 1.2.3 RAID Controller Module

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual A-6 Specifications Salvage the 2nd Temporary Failed Drive in a RAID 1, 3, 5, o

Strona 23

Appendix A: Subsystem Specifications Specifications A-7 This page is intentionally left blank.

Strona 24 - 1.2.6 BBU Module

Galaxy Raid GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual xii About This Manual This manual: • Introduces the Galaxy RAID GHDX2-

Strona 25 - 1.2.7 Power Supply Units

Spare Parts and Accessories B-1 Appendix B Spare Parts and Accessories B.1. Spare Parts Spare parts that come with the subsystem are liste

Strona 26 - Figure 1-11: PSU Module

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual B-2 Spare Parts and Accessories GHDX2-9274HANDLLCD Left-side forearm handle,

Strona 27 - 1.2.8 Cooling Modules

Appendix B Spare Parts and Accessories Spare Parts and Accessories B-3 This page is intentionally left blank.

Strona 28 - 1.2.9 Enclosure DIP Switches

Pinouts C-1 Appendix C Pinouts C.1. SFP Connector Pinouts Each of the SFP host or expansion ports is comprised of a case bottom, an EMI case, a

Strona 29 - 1.3. Subsystem Monitoring

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual C-2 Pinouts Pin Pin Name Pin Description 1 VEET Transmitter ground (common

Strona 30

Appendix C Pinouts Pinouts C-3 Table C-1: SFP Pin Out Definitions C.2. COM1 Serial Port Cable COM1 Cable: This cable connects between COM1 serial

Strona 31 - 1.4.3 Normalized Airflow

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual C-4 Pinouts C.3. COM1 Cable: DB9 Audio Jack Y-Cable Pinouts The 2-audio jacks

Strona 32

Appendix C Pinouts Pinouts C-5 Figure C-4: Connector Pinouts - Adapter Cable for COM2

Strona 33 - Hardware Installation

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual C-6 Pinouts CN1 Pin Number Pin Name 1 Ground 2 TXD 3 RXD CN2 Pin Number P

Strona 34

Appendix C Pinouts Pinouts C-7 Figure C-5: Null Modem Swap pin 2 and pin 3 Swap pin 4 and pin 6 Swap pin 7 and pin 8 Table C-5: Null Modem Pin

Strona 35

Galaxy Raid Installation and Hardware Reference Manual xiii These two documents can be found in the product utility CD included with your subsyst

Strona 36

Galaxy Raid GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual xiv equipment or result in personal injury. Warnings should be taken ser

Strona 37 -  Back-end PCBs

Galaxy Raid Installation and Hardware Reference Manual xv

Strona 38

Introduction 1-1 Chapter 1 Introduction 1.1. Product Overview This hardware manual briefly introduces the Galaxy GHDX2-2430S/R-16F4

Strona 39

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Introduction 1-2 A SAS expansion port comes with each RAID controller and pro

Strona 40

Chapter 1: Introduction 1-3 Figure 1-2: Galaxy 24-bay SATA RAID Subsystem Overview 1.1.1.2 Physical Dimensions The Galaxy HDX2 24bay subsystem co

Strona 41

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Introduction 1-4 1.1.1.3 Front Panel Overview Figure 1-3: Galaxy HDX2 24ba

Strona 42

Galaxy Raid GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual ii Contact Information Americas Rorke Data Inc 7626 Golden Triangle

Strona 43

Chapter 1: Introduction 1-51.1.1.5 Rear Panel Overview Figure 1-5: Galaxy GHDX2-2430R-24F4D Rear View Figure 1-6: Galaxy GHDX2-2430S-24F4D Rear

Strona 44 - 2.7.2 Installation Steps

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Introduction 1-6 Each RAID controller module comes with four (4) SFP host por

Strona 45

Chapter 1: Introduction 1-7the subsystem model name. A different name can be assigned for the subsystem or specific logical drives. This enables ea

Strona 46

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Introduction 1-8 contains no user-serviceable components. Only remove the con

Strona 47

Chapter 1: Introduction 1-9The dual-controller subsystem comes with a serial port Y-cable that allows you to access a surviving controller in the e

Strona 48

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Introduction 1-10 Figure 1-10: BBU Module, Controller Top Cover, and the Mod

Strona 49

Chapter 1: Introduction 1-11 Figure 1-11: PSU Module Each PSU module comes with a power socket for power cord plug-in. All three power supplies are

Strona 50

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Introduction 1-12 2 1. Warning messages are issued. 2. The subsystem is tem

Strona 51

Chapter 1: Introduction 1-13 Figure 1-12: Cooling Module 1.2.9 Enclosure DIP Switches Figure 1-13: Enclosure DIP Switches DIP switches are locat

Strona 52

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Introduction 1-14 1.3. Subsystem Monitoring The RAID subsystem comes with se

Strona 53 - 2.10.1 Component Description

Galaxy Raid Installation and Hardware Reference Manual iii Copyright 2007 This Edition First Published 2007 All rights reserved. This publication

Strona 54

Chapter 1: Introduction 1-15RAIDWatch: RAIDWatch is a premier, web-based or Java-based graphical user interface (GUI) that can be installed on an a

Strona 55

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Introduction 1-16 1.4.3 Normalized Airflow Proper subsystem cooling is referr

Strona 56

Chapter 1: Introduction 1-17 This page is intentionally left blank.

Strona 57 - Subsystem Monitoring

Hardware Installation 2-1 Chapter 2 Hardware Installation 2.1. Installation Overview This chapter gives detailed instr

Strona 58 - 3.2. Status-indicating LEDs

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-2 6. Rack installation: The enclosure chassis can b

Strona 59 - 3.2.1.2 Restore Default LED

Chapter 2 Hardware Installation Hardware Installation 2-3 Step 4. Verification of hard drive installation into the drive trays. Although SATA-II

Strona 60 - 3.2.3 LCD Keypad Panel

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-4 Figure 2-1: Installation Procedure Flowchart 2.5.

Strona 61 - System Monitoring

Chapter 2 Hardware Installation Hardware Installation 2-5 One (1) LCD keypad panel on the left side foldable handle  Back-end PCBs 2.6. Memory

Strona 62 - 3.2.4 Drive Tray LEDs

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-6 WARNING!  The controller board in the controller

Strona 63 - 3.2.5 BBU Module LED

Chapter 2 Hardware Installation Hardware Installation 2-73. The BBU module is hot-swappable and can be independently swapped from the controller.

Strona 64 - 3.2.6 PSU Module LED

Galaxy Raid GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual iv Warnings and Certifications Restricted Access Location: This equipm

Strona 65 - 3.2.7 Cooling Module LED

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-8 Figure 2-3: Removing the Controller Module Step 4

Strona 66 - 3.3. Audible Alarm

Chapter 2 Hardware Installation Hardware Installation 2-9 Figure 2-4: Accessing a DIMM Module Step 5. Install the replacement DIMM module. Care

Strona 67 - C Monitoring

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-10 3. Use the ejector levers on the sides to secure

Strona 68 - Connection and Operation

Chapter 2 Hardware Installation Hardware Installation 2-11 2.7. Rackmounting the Subsystem 2.7.1 Package Contents The slide rail kit (32- or

Strona 69 - 4.1.4 SFP Transceivers

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-12 Figure 2-7: Package Contents The rackmount rails

Strona 70 - Considerations

Chapter 2 Hardware Installation Hardware Installation 2-13so that the front and rear edges of the bracket fit the vertical rack posts. Figure 2-8:

Strona 71

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-14 Figure 2-9: Attaching M5 Cage Nuts to Rack Posts

Strona 72 - 4.2.5 Internal Connections

Chapter 2 Hardware Installation Hardware Installation 2-15 Step 6. Use the included crosshead round screws (#9 in the packing list) to secure two

Strona 73 - 4.2.7 ID/LUN Mapping

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-16 list) through the holes on the left- and right-sid

Strona 74 - 4.3 Fibre Channels

Chapter 2 Hardware Installation Hardware Installation 2-17impact during installation may damage your hard drives. Hard drives for the subsystem mu

Strona 75

Galaxy Raid Installation and Hardware Reference Manual v Use only shielded cables to connect I/O devices to this equipment. You are cautioned th

Strona 76 - IMPORTANT:

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-18 Figure 2-14: Installing a Hard Drive Step 2. Ad

Strona 77

Chapter 2 Hardware Installation Hardware Installation 2-192.9. Drive Tray Installation Before drive tray installation, you need to access the driv

Strona 78

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-20 Figure 2-18: Opening Front Bezel Step 3. Line u

Strona 79

Chapter 2 Hardware Installation Hardware Installation 2-21 Figure 2-20: Drive Tray Bezel Lock Rotation WARNING! All the drive trays must be insta

Strona 80

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-22 Figure 2-21: Cable Clamp and Cable Strap (Cable M

Strona 81 - Channel Settings

Chapter 2 Hardware Installation Hardware Installation 2-23and the ribbed side facing down. Press the release tab and adjust the position of the cab

Strona 82 - Tolerance

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual Hardware Installation 2-24 This page is intentionally left blank.

Strona 83 - Configuration Information

System Monitoring 1 3-1 Chapter 3 Subsystem Monitoring 3.1. Subsystem Monitoring Overview The Galaxy GHDX2-2430S-24F4D and GHDX2-24

Strona 84

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual System Monitoring 3-2  Audible alarm: The audible alarm on the subsystem co

Strona 85

Chapter 3 Subsystem Monitoring System Monitoring 3-3thresholds is violated. 4 BBU Link Green ON indicates BBU is present. 5 Hst Bsy Green F

Strona 86

Galaxy Raid GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual vi This device is in conformity with UL standards for safety. RoH

Strona 87

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual System Monitoring 3-4 remain intact after default restoration, configuration

Strona 88 - 4.4.4 Expansion Links

Chapter 3 Subsystem Monitoring System Monitoring 3-5 Figure 3-3: LCD Panel LEDs

Strona 89 - 4.5 Power On

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual System Monitoring 3-6 LED Name Color Status PWR Blue ON indicates that p

Strona 90 - 4.5.2 Power On Procedure

Chapter 3 Subsystem Monitoring System Monitoring 3-7 LED Name Color Status Drive Busy Blue/Amber FLASHING blue indicates there is read/wr

Strona 91 - 4.5.3 Power On Status Check

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual System Monitoring 3-8 FLASHING indicates the batteries are being charged. Tab

Strona 92

Chapter 3 Subsystem Monitoring System Monitoring 3-9 Figure 3-6: PSU Module LED Color Status Static Green The PSU is operating normally and

Strona 93 - GHDX2-24

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual System Monitoring 3-10 LED Status OFF The respective cooling fan is operatin

Strona 94 - 4.6 Power Off Procedure

Chapter 3 Subsystem Monitoring System Monitoring 3-11CPU Temperature 90ºC 5ºC Board Temperature 80ºC 5ºC Table 3-9: Default Threshold Valu

Strona 95

Subsystem Connection and Operation 4-1 Chapter 4 Connection and Operation This chapter outlines some basic rules you should follow when co

Strona 96 - Subsystem Maintenance

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-2 Subsystem Connection and Operation 4.1.2 FC Lasers CAUTION! Lasers can

Strona 97 - 5-2 Subsystem Maintenance

Galaxy Raid Installation and Hardware Reference Manual vii Table of Contents CHAPTER 1 INTRODUCTION 1.1. PRODUCT OVERVIEW ...

Strona 98

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-3 NOTE: LC connectors are small form-factor, fiber-optic con

Strona 99

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-4 Subsystem Connection and Operation Figure 4-1: Drive Mechanical Speed a

Strona 100 - 5-1: Removing the BBU Module

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-5 4.2.2 Fibre Channel Topologies The Fibre Channel standard sup

Strona 101

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-6 Subsystem Connection and Operation controllers to synchronize cached dat

Strona 102

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-7 4.3 Fibre Channels 4.3.1 Onboard Hub Settings The subsystem c

Strona 103

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-8 Subsystem Connection and Operation DIP Switch Configurations and Host Po

Strona 104 - 5-5: Removing the BBU Module

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-9 Figure 4-4: Host Port Bandwidth when the Onboard Hub is Enabl

Strona 105

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-10 Subsystem Connection and Operation on two controllers. If host ports ar

Strona 106 - 5-6: Removing the Power Cord

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-11 o Concern: One major concern for this topology is to avoid I

Strona 107 - 5-8: Dislodging the PSU

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-12 Subsystem Connection and Operation NOTE: To answer questions related t

Strona 108

Galaxy Raid GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual viii 2.7. INSTALLING THE OPTIONAL BBU...

Strona 109 - WARNING!

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-13 4.4 Host Connection Sample Topologies 4.4.1 Simple, Direct

Strona 110 - 5.6. Drive Tray Maintenance

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-14 Subsystem Connection and Operation Shown below is an example showing lo

Strona 111

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-15 Drive Via system bus, through the backplane 4th DIP Switch Hu

Strona 112

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-16 Subsystem Connection and Operation Figure 4-8: Clustered Servers with

Strona 113 - Subsystem Specifications

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-17 • This is a direct-attached configuration showing four (4) h

Strona 114

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-18 Subsystem Connection and Operation 4.4.3 Hub Disabled and Switched Fa

Strona 115

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-19 Data Path Connection Fault-tolerant data paths Host Channel B

Strona 116

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-20 Subsystem Connection and Operation

Strona 117 - A.6. RAID Management

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-21 4.4.4 Expansion Links A redundant-controller RAID enclosure

Strona 118

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-22 Subsystem Connection and Operation A single-controller RAID enclosure c

Strona 119 - Specifications A-7

Galaxy Raid Installation and Hardware Reference Manual ix 4.4.4 LCD Screen ...

Strona 120 - Spare Parts and Accessories

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-23  BBU: If used, make sure the optional BBU has been installe

Strona 121

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-24 Subsystem Connection and Operation Figure 4-13: Power Switch CAUTION

Strona 122

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-25  Audible alarm – If any errors occur during the initializat

Strona 123 - Pinouts

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-26 Subsystem Connection and Operation 4.5.4 LCD Screen When powering on th

Strona 124

Chapter 4: Subsystem Connection and Operation Subsystem Connection and Operation 4-27 4.6 Power Off Procedure To power off the subsystem, p

Strona 125 - C.2. COM1 Serial Port Cable

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 4-28 Subsystem Connection and Operation This page is intentionally left bla

Strona 126

Subsystem Maintenance 5-1 Chapter 5 Subsystem Maintenance 5.1. Introducing Subsystem Maintenance and Upgrading 5.1.1 Maintena

Strona 127 - Pinouts C-5

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 5-2 Subsystem Maintenance

Strona 128 - C.5. Null Modem

Chapter 5: Subsystem Maintenance Subsystem Maintenance 5-3 5.1.2 General Notes on Component Replacement  All of the components on the subsystem

Strona 129 - C.7. Power Socket

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual 5-4 Subsystem Maintenance BBU Module The BBU can be installed after the init

Komentarze do niniejszej Instrukcji

Brak uwag