Chapter 5: Subsystem Maintenance and Upgrading
Drive Tray Maintenance
5-17
WARNING!
Replacing the wrong drive in an array can fatally fail a RAID configuration. You
should identify a failed drive from the RAIDWatch GUI screen, by checking the drive
slot ID in the terminal screen, by checking the LEDs on the drive tray panel, and/or
use the identify/flash drive function in firmware. Please refer to Section 1.5 in your
Generic Operation Manual for details on this function.
Step 2. Open the front flap. To open the front flap, push the release button at
the front of the tray bezel. (See Figure 5-12) The front bezel will
automatically be lifted and the drive tray will be dislodged from the
chassis.
Figure 5-12: Front View of an Individual Drive Tray
Step 3. Remove the drive tray. To remove the drive tray from the enclosure,
the key-lock must be unlocked. (See Figure 5-13) To do this, turn the
key-lock on the front of the drive tray until the groove on its face is in
a horizontal orientation.